Quality assurance prevents defects by establishing effective processes; quality control tests software and its outputs against defined requirements. In control system software quality assurance, both matter: dependable operation depends on disciplined development and evidence that the finished system behaves as intended.

It is easy to treat the terms as interchangeable: both support quality and involve careful scrutiny. The difference is where that scrutiny applies. Assurance is proactive, shaping how work is planned, developed and reviewed. Control examines the resulting software to identify issues that need correction.

This article explains how risk-based assurance sets an appropriate level of rigour, when scripted or exploratory testing can help, and how audits, inspections and non-conformance tracking support a controlled process. It also clarifies verification and validation, helping you distinguish a well-designed quality process from checks that show whether a particular system meets its requirements.

Key Takeaways

  • Match assurance effort to the potential consequences of a software failure, using a proportionate risk assessment to guide the depth of review.
  • Choose scripted or exploratory testing according to the feature’s risk and the evidence needed to show it behaves as intended.
  • Use audits and inspections to identify process gaps, then track non-conformances through investigation and corrective action.
  • Keep the distinction clear: quality assurance improves the processes that prevent defects, while quality control checks outputs against requirements.

Risk-matched assurance activities

A risk-based framework directs quality activities towards software components with the greatest potential consequences. Assessment determines what to test, document and monitor within the management system.

Risk assessment and mitigation

Risk assessment considers how a software failure could affect system behaviour, operations or safety. Its findings guide mitigation and determine the depth of assurance for each component.

For example, a failure that disrupts a control sequence may require more rigorous analysis than a display issue with no effect on control. Safety integrity levels (SILs) express the required level of risk reduction; a higher integrity requirement calls for more demanding assurance and evidence. Appropriate activities depend on the function, possible harm and measures that reduce risk.

Revisit the assessment when requirements, interfaces or operating conditions change. This keeps assurance proportionate as the system develops.

Standards and assurance frameworks

Standards and frameworks provide a structured basis for defining assurance activities, but applicability depends on the system and its context. IEC 61508 addresses functional safety, while IEC 62443 concerns cybersecurity for industrial automation and control systems.

According to the International Organization for Standardization, ISO 14971 is a possible model for assessing software-related risks, although a simpler risk-assessment methodology is encouraged. The framework should connect identified hazards and failure paths to testing, review and documented decisions.

Standards do not require identical checks for every component. A risk-based approach helps teams choose appropriate analysis and evidence, supporting compliance without treating low- and high-consequence functions as equivalent. It also provides a traceable rationale for the assurance applied.

Defects and failure risks

Control software defects are faults that can make behaviour differ from intended requirements. Examples include incorrect logic, overlooked operating limits, mismatched interface data and configuration errors.

For instance, a control sequence might respond incorrectly to an unexpected input, or a component might use stale data from another system. Timing and integration faults can also cause inconsistent behaviour across connected equipment. These are risks to investigate, not a complete catalogue of possible defects.

Assurance links each plausible failure to a suitable check and mitigation. Reviewing requirements, interfaces and changed configurations helps reveal where behaviour could diverge from intended operation. Recording findings and their disposition gives the management system a clear basis for monitoring unresolved risks.

Scripted and unscripted testing

Testing checks whether software functions as intended, using planned procedures or exploratory investigation. Choose an approach that fits the feature’s risk and the evidence required.

Software testing types

Scripted testing follows written test-case instructions, allowing testers to perform defined actions and record results consistently. Tests can be fully or partly scripted, depending on the evidence needed. Unscripted testing uses scenarios, exploratory testing, ad hoc checks or error guessing to investigate behaviour beyond predetermined steps.

For a control function, a scripted test might check a defined input and expected output. An exploratory session might examine how the function responds to unusual sequences. Unit and functional tests examine components and requirements; integration and system tests assess interactions. Regression testing checks whether changes have disrupted existing behaviour, while acceptance testing evaluates fitness for intended use.

Vendor evidence and testing

Vendor evidence documents testing already performed on supplied software or components. It can inform assurance, but its value depends on how closely the tested version, configuration and operating context match the intended system.

Compare the evidence with requirements and note what it covers, such as functional results, known issues and test conditions. Plan additional checks for gaps, changed configurations and interfaces with other components. This prevents a supplier’s test record from being mistaken for proof of the integrated system’s behaviour.

In the United States, requirements depend on the sector and software’s role. FDA Part 11 obligations apply to electronic records and signatures in review workflows; industry standards and quality processes may also shape the evidence required.

Testing costs depend on the project, with scope, system complexity, risk, interfaces and required evidence all affecting the work involved.

Common tool categories include static-analysis tools, test execution environments and configuration-management systems. Management software can also record test cases, results, defects and approvals, helping organisations trace each finding to a function and its resolution.

Control System Software Quality Assurance vs. Quality Control

Audits, inspections, and non-conformance tracking

Audits assess whether teams follow defined quality processes; inspections examine specific software or system outputs. Together, they provide evidence for improvement and help keep decisions traceable.

Audit and inspection activities

An audit evaluates processes against planned arrangements, while an inspection checks an item, configuration or result against criteria. ISO 19011:2026 is an international guideline for auditing management systems, and ISO 9001:2015 Clause 9.2 covers internal audits.

An audit can review how requirements, changes and test results are controlled. An inspection might examine a software configuration or confirm that a device response meets its acceptance criteria. Set the scope and evidence according to the process being assessed, rather than treating every item as equally significant.

In manufacturing or a medical device environment, records can show how a process is monitored and findings are addressed. An assessment is most useful when it identifies a specific gap, its operational significance and the action needed to resolve it.

Documentation and traceability

Documentation and traceability connect intended use, risk decisions, tests, findings and approvals. They let a reviewer follow the rationale from a requirement through its assessment to the recorded outcome.

A useful assurance record identifies a feature’s intended use and risk determination, describes tests and issues, and records their disposition. It states whether results are acceptable, identifies the tester and assessment date, and includes appropriate review and approval.

For example, a changed control function should have a clear link between the change, relevant tests, results and any unresolved issue. This distinguishes evidence for the current configuration from records for an earlier version.

When a non-conformance is found, record what failed, where it occurred and its effect. Investigation should identify the cause, define corrective action and track its completion. ISO 9001 Clause 10.2 addresses corrective action and provides a basis for verifying CAPA effectiveness. Recording that verification supports continuous improvement, rather than closing a finding solely because an action was assigned.

Quality assurance and quality control differences

Quality assurance (QA) shapes processes to prevent defects; quality control (QC) checks outputs against established criteria. Both contribute to a quality management system, but they act at different points. QA asks whether work is designed and managed to produce dependable software. QC asks whether a particular component or supporting record meets its requirements.

Control system software QA differs from ordinary software QA because it must account for how software interacts with a physical process. A control function may influence equipment behaviour, so requirements and tests need to reflect intended operation and relevant risks. Reviewers might examine whether a control sequence meets its specified response, not just whether the code runs without errors.

QA is proactive: teams establish practices, responsibilities and review points before defects appear. QC is evaluative: testing or inspection checks a specific result against defined requirements. A QA review might assess how changes are managed; QC might test a changed component for mismatches. QC findings can then inform improvements to QA processes.

Verification and validation clarify what these checks establish. Verification asks whether a product conforms to its specification; validation asks whether it meets users’ actual requirements. A test may confirm that a function follows its written logic, while validation considers whether that behaviour supports the intended operational task. Link both forms of evidence to relevant requirements and records.

A quality management system brings these activities together. QA defines how work is planned and controlled; QC provides evidence about the resulting software and artefacts. Keeping the roles distinct helps teams determine whether a problem lies in the output, the process or both. Applicable quality processes can then address regulatory and customer requirements.

For control projects, apply this distinction from requirements through review and testing. Discuss control systems design when you need quality considerations built into the project lifecycle.

AAC LTD | All About Control

AAC LTD | All About Control helps organisations address control-system quality across design, integration and system change. Its automation engineering consultancy can support decisions about assurance activities, testing evidence and quality processes, while control systems design considers requirements across the project lifecycle.

For operational environments where dependable control is central, Mission Critical Control Systems provide a relevant context for applying these principles. AAC also undertakes SCADA Integration and Siemens S5 to S7 Migration, where a clear view of system requirements, interfaces and verification helps structure the work.

If you’re planning a control-system project, integration or migration and want to discuss its quality requirements, contact AAC LTD | All About Control.

Plan quality into the next change

The next system change is an opportunity to include quality decisions in engineering planning, rather than treating assurance as a final hurdle. Define how the software supports operations, identify the evidence needed for its intended use, and align reviews with the work as it develops. This connects control system software quality assurance to operational priorities and gives project teams a clear basis for decisions.

AAC LTD | All About Control works across SCADA Integration, Mission Critical Control Systems and Siemens S5 to S7 Migration. If a new project, integration or legacy-system change is prompting questions about assurance, a discussion can help establish how engineering support fits the work.

Contact AAC LTD | All About Control to discuss your control systems requirements and consider a considered next step.

Frequently Asked Questions

What Is the Difference Between Quality Control and Quality Assurance?

Quality assurance improves the way software work is planned and carried out; quality control examines a particular result. For example, a review process that checks requirements before development is assurance, while testing a completed alarm function against its expected response is control. A defect discovered during testing can reveal a need to improve the development process, not just correct that function.

What is software quality assurance for control systems?

Software quality assurance for control systems is the planned oversight of how software requirements, design, changes and test evidence are managed. It considers software’s role in controlling or monitoring an operational process, rather than treating it as an isolated application. A control system software quality assurance programme links requirements to reviews and test evidence, helping teams understand why a function was designed and assessed in a particular way.

What are the key software verification and validation steps for industrial control systems?

Verification establishes whether implementation meets its specification; validation assesses whether the system meets its intended operational needs. Start by linking each requirement to a design decision and a test. Examine individual functions, interactions between components and the integrated system’s behaviour. Then assess the system against representative operating needs, record deviations, and link changes to affected requirements and test results.

What testing methods are used for PLC, SCADA, and DCS software?

PLC, SCADA and DCS software can be assessed through unit, functional, integration and system testing. Regression testing is useful after a software change, while acceptance testing checks whether the system meets agreed operational needs. Performance or recovery testing can address relevant non-functional behaviour. Choose tests according to the software’s function: an interface between a PLC and SCADA system, for example, needs integration checks as well as tests of each function.

What are best practices for independent QA audits and supplier assessment of control system software?

Define an audit scope that identifies the software, configuration, processes and evidence under review. For supplier assessment, compare submitted test records with the supplied version and intended use, then identify gaps that need further assessment. An independent reviewer should check that conclusions follow from the evidence, including how exceptions were handled. Record findings, owners and corrective actions so the assessment informs later project decisions and reviews.